VENTILATION SYSTEMS
AIRFOX® S - Lateral ventilation system for built-in and TOP-MOUNTED BOXES
This small version of the AIRFOX® can be combined as a lateral ventilation system with the most diverse ROKA variants. So variable, so inconspicuous and yet so powerful - no other ventilation has ever suited so many situations as the AIRFOX® S. And of course it also hides so well that you don't see it after installation, but only notice it's there because of the good ventilation.
The models of the AIRFOX® S series
ROKA-THERM® 2 RG AIRFOX® S
- Installation box
- Closed on room side
- Standard box height 300 mm
- For electrically operated roller shutter hangings
ROKA-TOP® 2 RG AIRFOX® S
- Top box
- Easy assembly
- Closed on room side
- Standard box height 300 mm
- Incl. roller shutter, motor and rail system 75 mm ALU RG-TG
ROKA-SHADOW® 2 AIRFOX® S
- Installation box
- Closed on room side
- Standard box height 310 mm
- For EXTERNAL VENETIAN BLINDS
ROKA-TOP® 2 SHADOW AIRFOX® S
- Top box
- Easy assembly
- Closed on room side
- Standard box height 310 mm
- Incl. external venetian blind curtain and rail system
AIRFOX® S - Design variants
Suitable for New construction |
Suitable for Redevelopment |
Masonry overlay / Box overhang |
Air outlet lintel side |
Plaster / ETICS |
For Roller shutter |
For EXTERNAL VENETIAN BLINDS |
|
ROKA-THERM® 2 RG AIRFOX® S |
√ 1) | √ 1) | √ 1) / – | √ | √ / √ | √ | |
ROKA-TOP® 2 RG AIRFOX® S |
√ | √ | - – / √ 2) | √ | √ / √ | √ | |
ROKA-SHADOW® 2 AIRFOX® S |
√ 1) | √ 1) | √ 1) / – | √ | √ / √ | √ | |
ROKA-TOP® 2 SHADOW AIRFOX® S |
√ | √ | - – / √ 2) | √ | √ / √ | √ |
√ = fulfilled
1) Attention: the increased masonry support must be taken into account statically.
2) Attention the box overhang must be taken into account in the planning and, if necessary, statically.
AIRFOX® S
Breathe a sigh of relief - feel-good climate on principle
Main technical features
Performance data
Air performance | 7 - 35m3/h |
Power consumption | 4W (total system power) |
Intrinsic noise | from < 12.7 dB(A) (sound pressure level 1m frontal) |
Degree of heat provision | up to 91 % |
Standard sound level difference | up to 42 dB |
Cycle time | 60 sec. |
Filter class | G3 |
Minimum wall thickness | 300 mm (without plaster) |
Inner cover | 115 mm x 260 mm (W x H) |
Outdoor grille | depending on type |
Humidity sensor | optional |
Ventilation automation
Each room can be ventilated decentrally and thus adapted to individual requirements. For example, the desired ventilation in the bathroom can be set higher than in other rooms according to the high humidity. Simple operation directly at the window is guaranteed. Optionally, there is the possibility of automatic control by a humidity sensor.
A Setting the fan speed
- 1 | 7 cubic metres / hour
- 2 | 15 cubic metres / hour
- 3 | 25 cubic metres / hour
A Setting the fan speed
Unit switched off
One-way ventilation
Alternating ventilation (with heat recovery)
C Activation of the sleep mode
D Filter change due
E Switching on the shock ventilation:
- 35 cubic metres / hour
- (70 cubic metres / hour in conjunction with humidity sensor)
Humidity sensor
This is mounted above or below the control unit in a flush-mounted box and wired to the control unit.
Properties
- Detection of relative humidity in the range from 0% to 100%.
- Parallel measurement of ambient temperature
- Mounting in surface-mounted or flush-mounted boxes
- Compatible with 55 x 55 mm switch ranges
Application
- Active dehumidification in the bathroom or kitchen
- Optimisation of ventilation by recording the room temperature