Select page

VENTILATION SYSTEMS

AIRFOX® S - Lateral ventilation system for built-in and TOP-MOUNTED BOXES

This small version of the AIRFOX® can be combined as a lateral ventilation system with the most diverse ROKA variants. So variable, so inconspicuous and yet so powerful - no other ventilation has ever suited so many situations as the AIRFOX® S. And of course it also hides so well that you don't see it after installation, but only notice it's there because of the good ventilation.

The models of the AIRFOX® S series

ROKA-THERM® 2 RG AIRFOX® S
  • Installation box
  • Closed on room side
  • Standard box height 300 mm
  • For electrically operated roller shutter hangings
ROKA-TOP® 2 RG AIRFOX® S
  • Top box
  • Easy assembly
  • Closed on room side
  • Standard box height 300 mm
  • Incl. roller shutter, motor and rail system 75 mm ALU RG-TG
ROKA-SHADOW® 2 AIRFOX® S
  • Installation box
  • Closed on room side
  • Standard box height 310 mm
  • For EXTERNAL VENETIAN BLINDS
ROKA-TOP® 2 SHADOW AIRFOX® S
  • Top box
  • Easy assembly
  • Closed on room side
  • Standard box height 310 mm
  • Incl. external venetian blind curtain and rail system

AIRFOX® S - Design variants

  Suitable for
New construction
Suitable for
Redevelopment
Masonry overlay /
Box overhang
Air outlet
lintel side
Plaster /
ETICS
For
Roller shutter 
For
EXTERNAL VENETIAN BLINDS
ROKA-THERM® 2 RG
AIRFOX® S
1) 1) 1) / – √ / √  
ROKA-TOP® 2 RG
AIRFOX® S
- – / √ 2) √ / √  
ROKA-SHADOW® 2
AIRFOX® S
1) 1) 1) / – √ / √  
ROKA-TOP® 2 SHADOW
AIRFOX® S
- – / √ 2) √ / √  

√ = fulfilled

1) Attention: the increased masonry support must be taken into account statically.
2) Attention the box overhang must be taken into account in the planning and, if necessary, statically.

AIRFOX® S

Breathe a sigh of relief - feel-good climate on principle

Main technical features

Performance data

Air performance7 - 35m3/h
Power consumption4W (total system power)
Intrinsic noisefrom < 12.7 dB(A) (sound pressure level 1m frontal)
Degree of heat provisionup to 91 %
Standard sound level differenceup to 42 dB
Cycle time60 sec.
Filter classG3
Minimum wall thickness300 mm (without plaster)
Inner cover115 mm x 260 mm (W x H)
Outdoor grilledepending on type
Humidity sensoroptional

Ventilation automation

Each room can be ventilated decentrally and thus adapted to individual requirements. For example, the desired ventilation in the bathroom can be set higher than in other rooms according to the high humidity. Simple operation directly at the window is guaranteed. Optionally, there is the possibility of automatic control by a humidity sensor.

A Setting the fan speed

  • 1 | 7 cubic metres / hour
  • 2 | 15 cubic metres / hour
  • 3 | 25 cubic metres / hour

A Setting the fan speed

Unit switched off

One-way ventilation

Alternating ventilation (with heat recovery)

Bookmark

Bookmark

C Activation of the sleep mode

D Filter change due

E Switching on the shock ventilation:

  • 35 cubic metres / hour
  • (70 cubic metres / hour in conjunction with humidity sensor)

Humidity sensor

This is mounted above or below the control unit in a flush-mounted box and wired to the control unit.

Properties

  • Detection of relative humidity in the range from 0% to 100%.
  • Parallel measurement of ambient temperature
  • Mounting in surface-mounted or flush-mounted boxes
  • Compatible with 55 x 55 mm switch ranges

Application

  • Active dehumidification in the bathroom or kitchen
  • Optimisation of ventilation by recording the room temperature